How to maintain continuously transposed conductors?

If you’ve ever stood in a large power substation during a hot summer afternoon, watching transformers hum steadily while currents of thousands of amps flow through their windings, you might not realize that the quiet reliability of that equipment depends on a very specific component: continuously transposed conductors (CTCs). As a CTC supplier who’s spent the last 12 years working directly with power utilities, transformer manufacturers, and repair teams, I’ve seen firsthand how these thin, insulated strands of copper or aluminum—twisted and transposed to eliminate circulating currents—can make or break the lifespan of high-voltage transformers. But here’s the thing: even the highest-grade CTCs won’t perform at their best if they’re not maintained correctly. I’ve spoken to dozens of field technicians who assumed CTCs were “set it and forget it,” only to find out months later that poor maintenance had led to hot spots, reduced efficiency, and even unplanned outages. So today, I want to pull back the curtain on how to maintain CTCs properly, based on what I’ve learned working side-by-side with teams that keep our power grid running. Continuously Transposed Conductors

First, let’s get clear on why CTC maintenance matters in the first place. Unlike regular round copper wires, CTCs are made of dozens of narrow strands (usually between 0.8mm and 2mm thick for most transformer applications) that are transposed—meaning each strand moves to a different position in the cable’s cross-section at regular intervals. This transposition ensures that every strand carries the same amount of current, preventing circulating currents that create excess heat. But that same delicate transposition is also one of their biggest vulnerabilities. If a transposition point gets damaged, or if insulation on individual strands wears thin, those equal current flows break down, hot spots start to form, and over time, those hot spots can erode insulation, cause partial discharges, and shorten the transformer’s life by years. I had a client in the Midwest a few years back who skipped a routine CTC inspection, only to discover a transposition spot had loosened after a voltage surge. By the time they caught it, the damage had cost them $1.2 million in unplanned repairs and lost grid capacity. That’s why maintenance isn’t just a box to check—it’s a way to protect the big-ticket investments in our power infrastructure.

Let’s start with the most basic, and often overlooked, maintenance step: regular visual inspections. I know, it sounds simple, but you’d be surprised how many teams skip this because they assume CTCs are tucked away inside transformer windings, out of sight. Wait—you can’t see them when the transformer is fully assembled, right? So here’s the catch: visual inspections happen during planned maintenance outages, when you can access the winding, either by removing the top cover or pulling out the core-and-coil assembly. When you’re doing that, don’t just glance over the CTC bundle—systematically check every transposition point. Look for any signs of displacement: strands that have shifted out of their transposition sequence, gaps between strands that weren’t there before, or areas where the outer insulation (usually a layer of polyimide or paper) is cracked, frayed, or discolored. Discoloration is a big one—even a faint brown tint on a strand means that spot has run hotter than it should at some point, which is a warning sign of a developing problem.

I always tell teams to use a flashlight with a narrow beam when doing these checks. The small strands of CTC can hide damage in the crevices between them, and a focused beam will catch tiny cracks or gaps that a wide overhead light might miss. Another trick: bring a magnifying glass (10x magnification works well) to inspect individual strand insulation. I once had a technician point out a spot he thought was just a dust speck, but when we looked closer, it was a 0.3mm tear in the polyimide insulation of a strand right at a transposition point. If we’d missed that, within a month, that tear would have led to a short between strands, and the transformer would have failed on a peak load day. Visual inspections should happen at every planned outage, which for most transformers is every 3 to 5 years, depending on their operating voltage and load level. For transformers above 230kV, I recommend shortening that to every 2 years, just because the stakes are higher.

Next, testing the electrical performance of CTCs. Visual checks catch obvious damage, but they won’t pick up subtle issues like uneven current distribution between strands or partial insulation breakdown. That’s where electrical testing comes in, and there are two tests I swear by for CTC maintenance: the DC resistance test and the capacitance and dissipation factor (tan delta) test.

The DC resistance test is straightforward, but you have to do it right. The goal here is to measure the resistance of the entire CTC winding section and compare it to baseline data you should have from when the transformer was new. If the resistance is 5% or higher than the baseline, that’s a red flag—either strands have been damaged (which increases overall resistance) or circulating currents are forming, both of which mean the CTC is underperforming. Wait, you might be thinking: how do you do this without de-energizing the whole transformer? For planned outages, you can fully de-energize, ground, and discharge the transformer, which is the safest way. For minor checks between full outages, some teams use a low-voltage DC injection test that doesn’t require full de-energization, though I always recommend full de-energization for accurate results.

The tan delta test is a bit more specialized, but it’s worth the effort. Tan delta measures the insulation’s ability to resist electrical stress, and for CTCs, it can detect tiny, hidden defects in the strand insulation that visual checks miss. When a strand’s insulation is breaking down, the tan delta value will rise above the acceptable threshold (usually 0.5% for new CTCs, up to 1.5% for well-maintained ones—anything above that means you need to investigate). I work with a third-party testing lab that helps our clients run these tests, and they’ve told me that in 7 out of 10 cases where tan delta was elevated, the issue was a damaged strand insulation right at a transposition point—something you can’t see until you dig into the winding.

Then there’s handling and storage, which are part of long-term maintenance, even if they happen before the CTC is even installed. I see a lot of damage to CTCs before they ever get put into a transformer, because teams don’t handle them correctly during storage. CTCs are flexible, but they’re not unbreakable—sharp bends, heavy weights stacked on top of them, or being dragged across a concrete floor can kink the strands or crack insulation at transposition points. When I ship CTCs to a client, I always include a set of handling instructions, but half of them don’t read them, and end up calling me a few weeks later saying they have a bundle of CTCs with a kink. So for storage: keep CTC bundles on flat, stable surfaces, never stack more than two bundles high (the top one can put too much pressure on the bottom), and avoid bending them with a radius smaller than 10 times the width of the CTC bundle. For example, a standard 50mm wide CTC bundle needs a bend radius of at least 500mm—any smaller than that, and you’re risking damage to the transposition.

Another big part of maintenance is keeping the surrounding environment of the CTC winding clean. Dirt, moisture, and dust can get into the winding during manufacturing or over time, and they can cause partial discharges that eat away at strand insulation. That’s why when a transformer is opened for maintenance, you should always use dry, compressed air (at a pressure no higher than 2 bar—higher pressure can damage insulation) to gently blow out dust from the CTC bundle. Avoid using liquid cleaners, because any leftover moisture can get trapped between strands and cause insulation breakdown later. If there’s heavy dirt or oil buildup, use a lint-free cloth lightly dampened with isopropyl alcohol, and then dry the area immediately with compressed air. I once had a client in a coastal area whose CTC winding had salt buildup from a nearby ocean spray—they skipped cleaning it during an outage, and within a year, the salt had corroded the copper strands at transposition points, leading to a 20% drop in efficiency. That’s an easy fix that just didn’t get done.

What about if you do find damage? I get this question all the time, and the answer depends on the type and severity of the damage. Small, surface-level cracks in outer insulation that don’t affect the transposition? You can often fix that with a touch-up layer of polyimide tape, applied carefully over the damaged spot, making sure not to cover the transposition point itself. But if a transposition point is loose, or if multiple strands are damaged, that’s usually a job for a professional rewinder or a full CTC replacement. I’ve had clients try to “patch” damaged CTCs themselves, and 9 times out of 10, those patches fail within a year. CTC transposition is a precise process—each strand is placed in exactly the right position at a specific interval, and getting that wrong means circulating currents. So when damage is severe, don’t take shortcuts—order a replacement CTC from a reputable supplier (full transparency, that’s us) and have a certified technician install it.

Wait, let’s talk about operating conditions too, because maintenance isn’t just about fixing damage—it’s about preventing it in the first place. CTCs perform best when they operate at a steady temperature, so avoid overloading transformers beyond their rated capacity. I’ve seen transformers that were designed for 100MVA being run at 120MVA during peak summer, and that extra load causes CTC strands to expand and contract with heat, which can loosen transposition points over time. Also, make sure the transformer’s cooling system is working properly—hot spots from bad cooling are one of the top causes of CTC degradation. I recommend tracking the temperature of the CTC winding during operation with online temperature sensors, so you can catch spikes before they become permanent damage.

Let me wrap this up with a story that sums up everything I’ve learned. Last year, I worked with a utility company in Ohio that had a 150kV transformer that was starting to show signs of inefficiency—its energy losses were 8% higher than when it was new. The team had been doing annual visual checks, but they were only looking at the outside of the transformer, not accessing the winding. When they finally pulled out the core-and-coil assembly during a planned outage, they found that 12 transposition points on the low-voltage CTC winding had loosened, and three strands had broken insulation. They followed the steps we’ve talked about: they removed the damaged sections, cleaned the winding thoroughly, replaced the CTC segments with new ones (from our supplier line), and ran the DC resistance and tan delta tests. Six months later, the transformer’s energy losses were back down to 1.2%, matching its original performance. That’s the power of proper CTC maintenance—it’s not just about avoiding failures, it’s about getting the full lifespan and efficiency out of the equipment you already own.

At the end of the day, maintaining CTCs isn’t complicated, but it does require attention to detail and a commitment to regular, consistent checks. Too many teams see CTCs as a static component, something that’s installed and forgotten, but that couldn’t be further from the truth. They’re the workhorses of high-voltage transformers, and taking care of them will save you money in unplanned repairs, extend equipment life, and keep the power grid reliable for everyone.

If you’re looking to improve your CTC maintenance program, or if you need replacement CTCs for aging transformers, our team has years of experience working with utilities and manufacturers to provide tailored solutions. We understand that every transformer and application is different, so we can help you develop a maintenance schedule that fits your specific needs, from initial inspections to electrical testing to replacement parts.

Rectangular Insulated Aluminum Stranded Cable References

  1. American Society for Testing and Materials (ASTM). Standard Test Method for DC Resistance of Metallic Materials for Electrical Purposes. ASTM B193-19, 2019.
  2. Institute of Electrical and Electronics Engineers (IEEE). Guide for the Maintenance of Oil-Immersed Transformers. IEEE C57.12.90-2015.
  3. National Electrical Manufacturers Association (NEMA). Performance Guidelines for Continuously Transposed Conductors for Power Transformers. NEMA TP 1-2020.
  4. International Council on Large Electric Systems (CIGRE). Maintenance Practices for High-Voltage Transformer Windings. CIGRE Brochure 782, 2019.

Tianjin Jingwei Power Technology Co., Ltd.
As one of the most professional continuously transposed conductors manufacturers and suppliers in China, our products have good reputation in the market. We warmly welcome you to buy durable continuously transposed conductors for sale here from our factory. Good service and quality products are available.
Address: No.1 Chuangxin Rd. Xiaozhan Industrial Park, Jinnan District, Tianjin, China
E-mail: info@jwdc.cn
WebSite: https://www.jwdcs.com/